AVEVA Alarm Notification to Radios & Phones

AVEVA users need alarm data to reach operators beyond the control room. SeQent connects System Platform, InTouch, and PI System alarms to radios, phones, PA systems, and Andon boards with native integration and automatic escalation

Case Studies

Your AVEVA Alarms See Everything. Your Operators Should Too.

AVEVA System Platform, InTouch, and PI System give you deep visibility into your process. Alarm states, event logs, and historical trends are all there. But that visibility is often confined to control room workstations and engineering clients.

On the plant floor, in the field, between buildings, or during off-hours, operators and maintenance technicians are beyond the reach of an HMI screen. The alarm fires. Nobody sees it. The event persists.

SeQent Alarm Management closes that gap by connecting directly to AVEVA alarm and event sources, then delivering notifications to wherever your workforce actually is. For a broader look at how alarm data flows from control systems to notification platforms, read our article on Alarm and Event Ingestion: How Industrial Control Systems Feed Your Notification Platform.

How the Integration Works

SeQent integrates with AVEVA System Platform and InTouch through native data interfaces. Alarm data, including tag name, priority, area, description, and timestamp, flows into SeQent without middleware or custom development.

For PI System users, SeQent can ingest event and alarm data from the PI historian, enabling notification workflows triggered by historical data patterns or threshold breaches. Full details on SeQent’s AVEVA integration page.

Once ingested, SeQent routes each alarm based on configurable rules: shift schedule, operator role, geographic area, and alarm priority. Notifications are delivered via Motorola MOTOTRBO two-way radios, smartphones (push notification or SMS), email, PA speakers, Andon displays, Wi-Fi messengers, or pagers. If the first recipient does not acknowledge, the alarm escalates automatically through a defined chain.

Why AVEVA Users Need Alarm Notification Beyond the HMI

AVEVA environments tend to run in process-intensive industries: oil and gas, chemicals, water treatment, power generation, and large-scale manufacturing. These environments generate high alarm volumes and operate around the clock.

EEMUA Publication 191 (4th Edition, 2024) recommends no more than one alarm per operator per ten minutes during normal operations. In practice, many AVEVA-based plants exceed this threshold, especially during process upsets. Without intelligent routing, operators either receive all alarms (leading to fatigue) or miss critical ones buried in the flood.

SeQent’s schedule-aware routing and priority-based filtering ensure operators receive only the alarms relevant to their area and shift, with automatic escalation for unacknowledged critical alarms. For more on identifying where your alarm system may be falling short, see our blog on how to identify gaps.

Proven in the Field

SeQent has been deploying alarm notification infrastructure alongside AVEVA systems for over two decades. The integration is proven across industries and plant scales, from single-site operations to multi-site enterprises running AVEVA as their standard SCADA platform.